ECONAR®Earth Loop
Field
Wesley Homes Vertical Loop
Physical Data
Wesley Homes, a premier home builder in the greater Metropolitan
area of Minneapolis and St. Paul, has incorporated ECONAR GeoSource™ Heat
Pumps into many of his new homes. This home, in an upper end development
and with yard area at a premium, utilizes a vertical earth loop. The vertical loop system consists
of 10 holes and bored to a depth of 96 feet each and spaced 10 feet apart.
A high density PE3408 plastic pipe is inserted into every hole, connected
at the bottom with a u-bend. All underground connections are fusion welded
by the certified loop installer. The holes are then sealed using a bentonite
grout and piped together to a common manifold that runs into the building
below the frost line. The fluid that flows through the vertical loop system
is a combination of water and food grade antifreeze. The system has an
expected design life of 200 years and carries a 50-year warranty on the
pipe from the manufacturer.